  • Manual PAT Testers

    Seaward Electronic Ltd

    If you are looking for a manual PAT tester with a pass fail reading or a PAT tester with readings we have a solution for you. Carry out mains supply checks, IEC lead tests, Earth continuity tests at 200mA, Insulation resistance tests to 250V and 500V, and more with these popular testers. All of our manual PAT testers are available as kits to help you streamline the way you work.

  • Digital High Voltage Insulation Tester - Autoranging Insulation Measurements to 10MOhm

    Extech 380363 - Extech Instruments Corporation

    This Extech insulation tester measures up to 10GΩ with 250V, 500V and 1000V Test Voltages. Features include: Lo-Ohms for testing connections, analog bargraph for viewing trends, AC/DC Voltage measurement to 999V, manual data record/recall function (9 sets), and live circuit display warning and beeper. Can be used to test motor, transformer windings, instruments, and appliances, check for moisture in wire and cable assemblies, safely evaluate a new wiring installation, and check for carbon tracking in breakers, relays, and switches. Extech Insulation Testers offer high sensitivity to assure reliable monitoring of low resistance motor windings. Complete with carrying case, test leads, and 6 x AA batteries.

  • Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit

    72-7770 CAL DU - Tenma

    The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.

  • Hybrid Wound Component EST Scanner

    19035 - Chroma Systems Solutions, Inc.

    The quality verification test items for Wound Components consist of AC/DC Hipot tests and Insulation Resistance (IR) tests. Chroma integrates the above tests into the Hybrid 19035 Wound Component EST Scanner series to perform safety tests for motor, transformer, and heater related wound products. The wound component manufacturers performing quality verification testing will not only have reliable quality, but also can control product quality efficiently.

  • Hipot Tester

    19052/19053/19054 - Chroma ATE Inc.

    The Chroma Hipot Tester 19050 series provide 3 models for choice. The 19052 for AC/DC/IR Hipot testing and insulation resistance (IR) measurements, the 19053 which combines both AC and DC Hipot tests and IR measurements with 8HV scan channel capability into a single compact unit, and the 19054 which combines both AC and DC Hipot tests and IR measurements with 4HV scan channel capability into a single compact unit.

  • Medical System

    Sentinel I - Chroma Systems Solutions, Inc.

    The Sentinel I System provides fully automated Electrical Safety Testing to IEC/EN/UL/CSA 60601-1. This system is ideal for testing medical products with one or no patient connections or low volume production where operators can manually change leads between different patient connections. This is a 5 in one Hipot test system that can test Hipot, Ground Bond, Insulation Resistance, Patient Leakage, Earth Line Leakage, Enclosure Leakage and Patient Auxiliary Leakage.

  • Multi-purpose Tester

    DEL-101 - Standard Electric Works Co., Ltd

    ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.

  • Clamp Meters

    Klein Tools, Inc.

    Measures AC current via the clamp and AC/DC voltage, resistance and continuity via test-leadsBuilt to withstand a 3.3 ft. (1m) dropCAT III 600V, Class 2, Double insulation safety ratingBacklit display for clear readingsPowers off automatically after 15 minutes of non-use to conserve battery lifeIncludes a carrying case, test leads and 3 'AAA' batteriesLow battery indicator and easily accessible battery compartmentMeets requirements for use in basic and controlled electromagnetic environments like residential, office and light-industrial locationsOperating altitude to 6,562 ft (2,000 m)Operating temp: 32°F to 122°F (0°C to 50°C)

  • Non-contact Io/Ior Leakage Clamp Meter

    MCL-800IRV - MULTI MEASURING INSTRUMENTS Co., Ltd.

    ・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・Calculable insulation resistance value(MΩ)by voltage & current (only in case of using direct voltage input sensors)・Available measurement for 3P/4W star connection.

  • Testing Services

    ION Corporation

    *Programmable Multipoint Tester*Over 8,000 programmable test points (DWV, Capacitance, Insulation Res., 2/4-Wire Resistance, etc.)*1500VDC / 1000 VAC Dielectric Withstanding Voltage (DWV)/ Hi-Pot (Programmable Dwell times)*Full Electronics laboratory complete with state of the art testing equipment*Custom Unit Testing (Designing of Specialized Test fixtures)*EMI Testing*Temperature and Humidity Testing*Shock Testing*Vibration Testing*Sand and Dust / Altitude Testing*Military Qualification Tests Performed

  • Hipot Testers

    Hypot® Series - Associated Research

    The Hypot Series sets the standard for safety and efficiency in production line Hipot Testing. Whether your application requires AC Withstand tests, DC Withstand tests, or Insulation Resistance tests, The Hypot Series provides innovations that will allow you to begin achieving best practices for safety and efficiency without the need for an expensive automated test system or connection to a PC. You can even connect the Hypot Series with the HYAMP Series to form a seamless safety compliance system for Hipot and Ground Bond Testing.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL - Tenma

    The 72-7226 CAL from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL DU - Tenma

    The 72-7226 CAL DU from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.

    72-7226 CAL D - Tenma

    The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.

  • Automatic Wire Test Set

    AWTS - Eclypse International

    The Automatic Wire Test Set (AWTS) is automated test equipment that aids wiring diagnostics of electrical and electronic devices. The Test Control Unit (TCU) uses resistance measurements, capacitance measurements, and AC/DC voltage measurements to perform continuity, insulation, and isolation tests. The AWTS Laptop CPU, hereafter referred to as CPU, controls the AWTS. The Eclypse Language Integrated Test Environment (ELITE) is application software that controls the TCU. The majority of the hardware for a test is contained in the TCU. The 128pin connector on the TCU front panel provides 128 energizable test points. Switch Modules (SM) can be connected in sequence or daisy chained to the TCU and provide an additional 1024 test points; 128 of those are energizable.